Furnace No. 1000 - VFS Vacuum Furnace Systems - Super Quencher

 

2 Bar Vacuum
 100 Horse Power Blower for Quench gas circulation
 24" x 24" x 36" T.U.S. Working Zone (1000 LBS CAP)
 Temperature Uniformity (+/-10F)
 Model # HL 36eq2 S/N VF437
 Leybold Ion Gauge CM31 S/N: 89689D951200042
 Leybold Cold Cathode CM31 S/N: 89689D951200042
 Digital Display DPR 3000 S/N: 91411272764005
 Programmer/Controller-Compu Vac 2000 Microprocessor
 Based Interface with 486 flat panel computer including the following:
 
 Active matrix 30 color touch screen for furnace control,
 vacuum pump control, enter and download program recipes,
 alarm status, and overall view of all furnace functions.
 S/N 15672-16278-74257.
 
 The recipe program allows the operator to download and
 upload stored recipes. Modifications to store recipes can
 only be edited with a level One Password (via Burton Q.A). 
 Historical trending data is logged in a binary format on a
 PCMCIA hard drive within the control panel. 
 Data can be viewed on the panel in either trend of tabular form. 
 The panel allows the operator to send historical data screen
 directly to a printer.  All thermocouples and vacuum readings
 are collected in tabular mode regardless of the active pens in the
 trend mode.  The recording pens can be reassigned on the Fly allowing
 selection of individual thermocouples and/or vacuum readings for
 comparison.
 
 Honeywell UDC 2000 S/N 953OY522030700009
 Digital Microprocessor for excessive temperature protection
 
 Leybold- Digital Vacuum Gauge Model CM 31 S/N 89689D951200042
 This vacuum gauge allows the operator to view both a graphical
 and a numeric representation of the vacuum level being measured. 
 
 The CM31 uses- Thermoval TR211 Priani Sensors to provide signals
 indicating vacuum pressures from the 1000 to 1X 10-4 Torr range.
  
 The CM31 also uses a penningvac PR25 Cold Cathode (ion) tube for
 indicating vacuum pressures from the 10-2 to 10-7 torr range. 
 
 The CM31 is configured to automatically engage the penning vac tube
 when the pressure of the chamber priani is 8 x 10-3 torr below and
 disengage when chamber pressure is 3.7 x 10-2 or above.
          
 Honeywell DPR 3000 Multi-Microprocessor based 32 channel recorder
 (this 2nd recorder employs Type .S. and type .K. thermocouples)
 S/N 721060344-050-14-9704
 
 Programmer Logic Controller ( Siemans Model 405)
 The Siemans 405 is a modular hardware controller consisting of a CPU.
 A power supply card rack chassis.  Individual input and output card.
 Each processor has a battery back-up to maintain the programming when/if
 the power is turned off.
 
 APC-American Power Conversion. Un-interruptible power supply
 Model 600 S/N 096026770642
 
 600 VA (Volt-Amps) for 145 minutes of 400 amp service in the event
 of main power supply loss.
 
 U.S. Robotics- Phone modem with 28,000 data for downloading or uploading
 at remote locations .
 *Patent pending*  S/N 008390147745888
 Vacuum System-      
 A) Stokes model 412, 300 CFM-Roughing Pump
 B) Stokes model 615, 1600 CFM-Booster Pump
 C) Varian Model HS-16, 10,000 LPS-Diffusion Pump
 D) Allocate Model UT2055, 3.2 CFM-Holding pump
 E) Partial Pressure Gas System will introduce
    Nitrogen gas directly into the HOT Zone if required
 Chamber-
 A) Pneumatically operated autoclave type door
 B) Two ports for furnace control thermocouples
 C) Six inch flange port for up to twelve (12) work load thermocouples
 Gas Quench System-
 A) Gas back-fill Reserve Reservoir (515 Gallon) for rapid  quenching
 B) External Gas Quench System consist of 100 horse power gas distribution
    blower for super quenching at 15 PSIG positive pressure. (2 Bar)Eq:
    set point temp. of 2000F to below 400F within 9 mins.

 

 

 

Copyright© 2005 Burton Ind. Inc.,
                     All rights reserved.
home      news      services      facilities      approvals     schedule      F.A.Q.       links       contact