Frequently asked questions about aluminum temper conversion.
The following tables will show the most common temper conversions.
Click here for a printer-friendly PDF version of the following tables.
***Adobe Acrobat v6.0 or higher is required to view this document***
.
:.: Click here to download the latest version of Adobe Acrobat. :.:.
Our Certifications
NADCAP Quality Systems Certification
NADCAP Heat Treat Certification
(click on any of the above to view the document)
General Temper Conversions For 7075 Material
General Temper Conversions For 7075 Material |
"0" |
01 |
T6 |
T651 |
T6511 |
T73 |
T7351 |
T73511 |
T76 |
T7651 |
T76511 |
STARTING MILL
TEMPER BELOW |
|
|
|
|
|
|
|
|
|
|
|
"0"-Condition |
|
no |
yes** |
no |
no |
yes** |
no |
no |
yes** |
no |
no |
T6 |
yes |
no |
|
no |
no |
yes |
no |
no |
yes |
no |
no |
T651 |
yes |
no |
yes** |
|
no |
yes** |
yes |
no |
yes** |
yes |
no |
T6511 |
yes |
no |
yes** |
no |
|
yes** |
no |
yes |
yes** |
no |
yes |
T73 |
yes |
no |
yes** |
no |
no |
|
no |
no |
yes** |
no |
no |
T7351 |
yes |
no |
yes** |
no |
no |
yes** |
|
no |
yes** |
no |
no |
T73511 |
yes |
no |
yes** |
no |
no |
yes** |
no |
|
yes** |
no |
no |
T76 |
yes |
no |
yes** |
no |
no |
yes** |
no |
no |
|
no |
no |
T7651 |
yes |
no |
yes** |
no |
no |
yes** |
no |
no |
yes** |
|
no |
T76511 |
yes |
no |
yes** |
no |
no |
yes** |
no |
no |
yes** |
no |
|
** Can be achieved by resolution and/or resolution and artificial age. This process can cause
distortion depending on material thickness and configuration.

General Temper Conversions For 6061 Material
General Temper Conversions For 6061 Material |
"0" |
T4 |
T42 |
T6 |
T62 |
STARTIING MILL TEMPER BELOW
|
|
|
|
|
|
|
|
yes** |
yes** |
yes** |
yes** |
T4 |
yes |
|
yes** |
yes |
yes** |
T42 |
yes |
yes** |
|
yes** |
yes |
T6 |
yes |
yes** |
yes** |
|
yes** |
T62 |
yes |
yes** |
yes** |
yes** |
|
** Can be achieved by resolution and/or resolution and artificial age. This process can cause distortion depending on material thickness and configuration.

General Temper Conversions For 2024 Material
General Temper Conversions For 2024 Material |
"0" |
T3 |
T351 |
T3511 |
T4 |
T42 |
T6 |
T62 |
T81 |
T851 |
T8511 |
STARTING MILL TEMPER BELOW |
|
|
|
|
|
|
|
|
|
|
|
"0"-Condition |
|
no |
no |
no |
yes** |
yes** |
yes** |
yes** |
no |
no |
no |
T3 |
yes |
|
no |
no |
yes** |
yes** |
yes** |
yes** |
yes |
no |
no |
T351 |
yes |
no |
|
no |
yes** |
yes** |
yes** |
yes** |
no |
yes |
no |
T3511 |
yes |
no |
no |
|
yes** |
yes** |
yes** |
yes** |
no |
no |
yes |
T4 |
yes |
no |
no |
no |
|
yes** |
yes |
yes** |
no |
no |
no |
T42 |
yes |
no |
no |
no |
yes** |
|
yes** |
yes |
no |
no |
no |
T6 |
yes |
no |
no |
no |
yes** |
yes** |
|
yes** |
no |
no |
no |
T62 |
yes |
no |
no |
no |
yes** |
yes** |
yes** |
|
no |
no |
no |
T81 |
yes |
no |
no |
no |
yes** |
yes** |
yes** |
yes** |
|
no |
no |
T851 |
yes |
no |
no |
no |
yes** |
yes** |
yes** |
yes** |
no |
|
no |
T8511 |
yes |
no |
no |
no |
yes** |
yes** |
yes** |
yes** |
no |
no |
|
** Can be achieved by resolution and/or resolution and artificial age. This process can cause distortion depending on material thickness and configuration.

Hardness Conversion Chart
C
Scale |
A
Scale |
15-N
Scale |
KSI
PSI |
|
C
Scale |
A
Scale |
15-N
Scale |
KSI
PSI |
80 |
92.0 |
96.5 |
N/A |
|
49 |
75.2 |
85.0 |
246 |
79 |
91.5 |
96.3 |
N/A |
|
48 |
74.7 |
84.5 |
238 |
78 |
91.0 |
96.0 |
N/A |
|
47 |
74.1 |
83.9 |
229 |
77 |
90.5 |
95.8 |
N/A |
|
46 |
73.6 |
83.5 |
221 |
76 |
90.0 |
95.5 |
N/A |
|
45 |
73.1 |
83.0 |
215 |
75 |
89.5 |
95.3 |
N/A |
|
44 |
72.5 |
82.5 |
208 |
74 |
89.0 |
95.0 |
N/A |
|
43 |
72.0 |
82.0 |
201 |
73 |
88.5 |
94.8 |
N/A |
|
42 |
71.5 |
81.5 |
194 |
72 |
88.0 |
94.5 |
N/A |
|
41 |
70.9 |
80.9 |
188 |
71 |
87.0 |
94.3 |
N/A |
|
40 |
70.4 |
80.4 |
182 |
70 |
86.5 |
94.0 |
N/A |
|
39 |
69.9 |
79.9 |
177 |
69 |
86.0 |
93.5 |
N/A |
|
38 |
69.4 |
79.4 |
171 |
68 |
85.6 |
93.2 |
N/A |
|
37 |
68.9 |
78.8 |
166 |
67 |
85.0 |
92.9 |
N/A |
|
36 |
68.4 |
78.3 |
161 |
66 |
84.5 |
92.5 |
N/A |
|
35 |
67.9 |
77.7 |
156 |
65 |
83.9 |
92.2 |
N/A |
|
34 |
67.4 |
77.2 |
152 |
64 |
83.4 |
91.8 |
N/A |
|
33 |
66.8 |
76.6 |
149 |
63 |
82.8 |
91.4 |
N/A |
|
32 |
66.3 |
76.1 |
146 |
62 |
82.3 |
91.1 |
N/A |
|
31 |
65.8 |
75.6 |
141 |
61 |
81.8 |
90.7 |
N/A |
|
30 |
65.3 |
75.0 |
138 |
60 |
81.2 |
90.2 |
N/A |
|
29 |
64.6 |
74.5 |
135 |
59 |
80.7 |
89.8 |
351 |
|
28 |
64.3 |
73.9 |
131 |
58 |
80.1 |
89.3 |
338 |
|
27 |
63.8 |
73.3 |
128 |
57 |
79.6 |
88.9 |
325 |
|
26 |
63.3 |
72.8 |
125 |
56 |
79.0 |
88.3 |
313 |
|
25 |
62.8 |
72.2 |
123 |
55 |
78.5 |
87.9 |
301 |
|
24 |
62.4 |
71.6 |
119 |
54 |
78.0 |
87.4 |
292 |
|
23 |
62.0 |
71.0 |
117 |
53 |
77.4 |
86.9 |
283 |
|
22 |
61.5 |
70.5 |
115 |
52 |
76.8 |
86.4 |
273 |
|
21 |
61.0 |
69.9 |
112 |
51 |
76.3 |
85.9 |
264 |
|
20 |
60.5 |
69.4 |
110 |
50 |
75.9 |
85.5 |
255 |
|
|
|
|
|
***The conversion values are approximate values only. They have been independently developed and appear to be consistent with ASTM E-140 and A-370.
|

Required Hardness for Precipitation-Hardening Corrosion-Resistant Steels After Aging
.
.::PLEASE ALLOW TIME FOR THE IMAGES TO LOAD::..
It may take several minutes to load depending on your connection speed.
Click the image below for a full screen image

Round Test Bar Requirements For Pull Test
..::PLEASE ALLOW TIME FOR THE IMAGES TO LOAD::..
It may take several minutes to load depending on your connection speed.
Click the image below for a full screen image.

Flat Test Bar Requirements For Pull Test
..::PLEASE ALLOW TIME FOR THE IMAGES TO LOAD::..
It may take several minutes to load depending on your connection speed.
Click the image below for a full screen image.

Decarb Specimen Sizes:
1/2 to 3/4" DIA
1/8 to 1/4" Thick max
Mill decarb to be removed from circumfrence ground to 125 finish on both sides
|